Three boxes and a portable, all 24 VDC, all watched by the boat's automation rather than left to their own thermostats. | |||
== The boxes == | |||
* '''Two freezers''', keel-cooled — '''Frigoboat''' systems with Danfoss compressors, each running to its own bronze keel-cooler plate through the hull, with its own sacrificial pencil zinc and a bonding wire back to the main engine's battery negative. | |||
< | * '''One refrigerator''' — currently a standalone '''Dometic''' unit with its own self-contained compressor, not keel-cooled. Its keel cooler is '''already mounted''', ahead of a planned conversion to a built-in Frigoboat system at the next haul-out — pull the Dometic, build a new box, install the evaporator plate and compressor, rewire, new thermostat. Not started as of September 2026. | ||
</ | * '''One portable''' — an Engel, dual-voltage (110 VAC shore/inverter or 12/24 VDC underway), for overflow or when the boat's own boxes are full. | ||
Keel-cooled refrigeration went live 7–12 June 2026 — refrigerant and electrical to both freezer compressors, the fridge wired and cooling the same week. Keel coolers are ineffective out of the water, so haul-out periods mean running on ice or the portable. | |||
== Monitoring == | |||
Eight '''RuuviTag''' wireless sensors cover the boat, four of them refrigeration: both freezers, the fridge, and the Engel (the other four are salon, berth, engine room, and helm). They report into the Cerbo GX and the automation Pi, with over-temperature thresholds set per box — freezers around 32°F, the fridge and the Engel around 50°F. A refrigeration over-temp trips '''AL-17''' on the master alarm panel — see [[Boat Automation and Monitoring]]. | |||
<div style="border-left:4px solid #c9a227;padding:0.4em 1em;background:#fdf6e3"> | |||
'''Still open (September 2026)''' | |||
* Fridge → built-in Frigoboat conversion — queued for the next haul-out, keel cooler already in place | |||
</div> | |||
[[Category:Refit]] | |||
Revision as of 01:28, 12 September 2026
Part of the Refit - 2025/ 2026 series. Draft — Lee to review. As-built to the September 2026 break.
Three boxes and a portable, all 24 VDC, all watched by the boat's automation rather than left to their own thermostats.
The boxes
- Two freezers, keel-cooled — Frigoboat systems with Danfoss compressors, each running to its own bronze keel-cooler plate through the hull, with its own sacrificial pencil zinc and a bonding wire back to the main engine's battery negative.
- One refrigerator — currently a standalone Dometic unit with its own self-contained compressor, not keel-cooled. Its keel cooler is already mounted, ahead of a planned conversion to a built-in Frigoboat system at the next haul-out — pull the Dometic, build a new box, install the evaporator plate and compressor, rewire, new thermostat. Not started as of September 2026.
- One portable — an Engel, dual-voltage (110 VAC shore/inverter or 12/24 VDC underway), for overflow or when the boat's own boxes are full.
Keel-cooled refrigeration went live 7–12 June 2026 — refrigerant and electrical to both freezer compressors, the fridge wired and cooling the same week. Keel coolers are ineffective out of the water, so haul-out periods mean running on ice or the portable.
Monitoring
Eight RuuviTag wireless sensors cover the boat, four of them refrigeration: both freezers, the fridge, and the Engel (the other four are salon, berth, engine room, and helm). They report into the Cerbo GX and the automation Pi, with over-temperature thresholds set per box — freezers around 32°F, the fridge and the Engel around 50°F. A refrigeration over-temp trips AL-17 on the master alarm panel — see Boat Automation and Monitoring.
Still open (September 2026)
- Fridge → built-in Frigoboat conversion — queued for the next haul-out, keel cooler already in place